12" Axial Ventilation Fan: Difference between revisions
m (→Current Usage: Added predetermined fan speeds.) |
|||
(One intermediate revision by the same user not shown) | |||
Line 28: | Line 28: | ||
== Current Usage == | == Current Usage == | ||
Please run the ceiling fan when the laser cutter is running. Use the '''HAL display''''s '''Fan''' tab to control the fan. | Please run the ceiling fan when the laser cutter is running. Use the '''HAL display''''s '''Fan''' tab to control the fan. | ||
<gallery mode=packed-hover widths=350px heights=300px> | |||
File:HAL_Display_Fan_Simple.png|HAL Display Fan Control Simple View | |||
File:HAL_Display_Fan_Advanced.png|HAL Display Fan Control Advanced View | |||
</gallery> | |||
As of 2021-04, the fan was upgraded to a Baldor CM3537 VFD controlled 3 phase motor. The VFD is Invertek model ODE-3-110043-1012. | As of 2021-04, the fan was upgraded to a Baldor CM3537 VFD controlled 3 phase motor. The VFD is Invertek model ODE-3-110043-1012. | ||
=== Found Fan Speeds === | === Found Fan Speeds === | ||
The fan seems to hit a resonant node around | The fan seems to hit a resonant node around 36Hz, so that frequency is avoided. The following are frequencies are empirically found to work well with the fan and not confuse the humans. | ||
{| class=wikitable | {| class=wikitable | ||
!Name | !Name | ||
Line 45: | Line 49: | ||
|0 Hz | |0 Hz | ||
|24 Hz | |24 Hz | ||
| | |32 Hz | ||
|42 Hz | |42 Hz | ||
|60 Hz | |60 Hz |
Latest revision as of 13:55, 3 September 2022
Location: On the Ceiling towards the back |
Fan |
---|
Brand: Unknown |
Background
The 12" Axial Ventilation ceiling fan of questionable pedigree is in a sheet metal and fiberboard enclosure of questionable pedigree.
In the time when droplets of water fall from the sky, the fan enclosure leaks water into the interior of the makerspace. Nobody knows why.
The ceiling fan is placed on a ceiling perforation that was made before the industrial unit was rented by the makerspace. The perforation was originally for an 18" turbine ventilator.
Underneath the ceiling perforation, a plenum box of similarly questionable pedigree was constructed out of paper-backed foam board found in the dumpster.
Current Usage
Please run the ceiling fan when the laser cutter is running. Use the HAL display's Fan tab to control the fan.
As of 2021-04, the fan was upgraded to a Baldor CM3537 VFD controlled 3 phase motor. The VFD is Invertek model ODE-3-110043-1012.
Found Fan Speeds
The fan seems to hit a resonant node around 36Hz, so that frequency is avoided. The following are frequencies are empirically found to work well with the fan and not confuse the humans.
Name | Off | Low | One | Two | High | Turbo |
---|---|---|---|---|---|---|
Frequency | 0 Hz | 24 Hz | 32 Hz | 42 Hz | 60 Hz | 80 Hz |
Old Modbus code reference
This code can be used to run the VFD while the Haldor Fan Controller is under development, but the drive is currently configured to be controlled via the control panel.
You may gain access to the controller by contacting User:BLu.
import minimalmodbus from multitimer import MultiTimer instr = minimalmodbus.Instrument("/dev/ttyS2", 1) instr.serial.baudrate = 38400 runcmd = 0 # these registers can be found in the invertek manual CONTROL_WORD = 0 FREQ_SETPOINT = 1 DRIVE_STATUS = 5 # these control word bits can be found in the invertek manual ON = 1 FAULT_RESET = 4 def renew(): global runcmd instr.write_register(CONTROL_WORD, runcmd) timer = MultiTimer(interval = 1, function = renew) timer.start() instr.read_register(DRIVE_STATUS) instr.write_register(FREQ_SETPOINT, 300) runcmd = ON
Future Usage
The ceiling fan is planned to also vent from the 3d printers when the ABS fume extraction apparati are installed. Please wait warmly.
The MODBUS code for controlling the fan is still under development.